a) Stop the SySAM service
b) Slightly modify the license file of the SySAM machine by fully qualify the machine name with its domain name (same as the license file from the borrowing system)
SERVER DEVSERV01.adp1.cibc.pte 001012ac3545
VENDOR SYBASE
USE_SERVER
c) Restart the SySAM service
d) Perform a status inquiry using lmtools.exe (there is a button for that)
e) In the borrowing system, there is one line missing in the .lic file (it must match the license from the SySAM machine):
SERVER DEVSERV01.adp1.cibc.pte ANY
VENDOR SYBASE